{"id":343,"date":"2018-02-01T10:35:23","date_gmt":"2018-02-01T10:35:23","guid":{"rendered":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/?p=343"},"modified":"2022-07-26T08:44:09","modified_gmt":"2022-07-26T06:44:09","slug":"comparativa-generadores-hipoxia-mag-20-vs-summit-ii","status":"publish","type":"post","link":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/comparativa-generadores-hipoxia-mag-20-vs-summit-ii\/","title":{"rendered":"Comparativa Generadores de Hipoxia MAG-20 Vs SUMMIT II"},"content":{"rendered":"\n<h5 class=\"wp-block-heading\">Si est\u00e1s interesado en realizar entrenamiento en altitud simulada, ya sea con el fin de Aclimataci\u00f3n a la Altura, Mejora del Rendimiento o Salud, Biolaster te ofrece diversas opciones:<\/h5>\n\n\n\n<p>Altipower Pro y los <strong>generadores de hipoxia&nbsp;<\/strong><a href=\"https:\/\/www.biolaster.com\/productos\/hipoxia\/hipoxia-vital-air\/\">Hypoxicators Vital Air<\/a> \u2013 <a rel=\"noopener noreferrer\" href=\"https:\/\/shop.biolaster.com\/es\/rendimiento\/774-hypoxicator-portatil-one-plus-r3.html\" target=\"_blank\">R3 \u2013 One Plus R3<\/a>, Everest Summit II y MAG-20.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft\"><a href=\"https:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-content\/uploads\/sites\/5\/2018\/02\/comparativa-gen.jpg\"><img decoding=\"async\" src=\"https:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-content\/uploads\/sites\/5\/2018\/02\/comparativa-gen.jpg\" alt=\"\" class=\"wp-image-355\"\/><\/a><\/figure><\/div>\n\n\n\n<p>Entre\u00a0 \u00e9stos, los <strong>generadores de hipoxia;<\/strong>\u00a0Mountain Air Generator MAG-20 de HIGHER PEAK y el <a rel=\"noopener noreferrer\" href=\"https:\/\/shop.biolaster.com\/es\/hipoxia\/82-generador-hipoxia-hypoxico-summit-ii.html\" target=\"_blank\">Everest Summit II de HYPOXICO<\/a> representan la opci\u00f3n m\u00e1s interesante en relaci\u00f3n Calidad-Precio-Prestaciones, posibilitando efectuar los tres tipos de hipoxia habituales, <strong>Hipoxia Nocturna <\/strong>&#8211; <strong>Hipoxia en Reposo<\/strong> \u2013 <strong>Hipoxia en Ejercicio.<\/strong><\/p>\n\n\n\n<p>Te ofrecemos la siguiente tabla\u2013resumen de caracter\u00edsticas principales de ambos sistemas para ayudarte en la elecci\u00f3n del m\u00e1s apropiado para ti:<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-content\/uploads\/sites\/5\/2018\/02\/comparativa.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"167\" src=\"https:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-content\/uploads\/sites\/5\/2018\/02\/comparativa-300x167.jpg\" alt=\"Cuadro Comparativo Generadores de Hipoxia Mag 20 y Summit II\" class=\"wp-image-345\"\/><\/a><\/figure>\n\n\n\n<p>En el caso de elegir el <strong>Generador de Hipoxia&nbsp;SUMMIT II<\/strong>, se habr\u00eda de adquirir aparte el <strong><a href=\"https:\/\/shop.biolaster.com\/es\/hipoxia\/86-adaptadoraltaaltitud.html\">Adaptador de Alta Altitud<\/a>&nbsp;<\/strong>que posibilita su uso en altitudes simuladas desde <em>3800m hasta 6400m<\/em>.<\/p>\n\n\n\n<p>El Generador de Hipoxia\u00a0<strong>MAG-20<\/strong> permite ajustar la altitud simulada de 0 a 6300m sin acople extra, con lo cual en ese aspecto es m\u00e1s ventajoso.<\/p>\n\n\n\n<p>El punto destacable del <strong>SUMMIT II<\/strong> es que entrega un <u>20% m\u00e1s<\/u> de volumen de aire Hipox\u00edco que el <strong>MAG-20 <\/strong>hasta 3200m, 120 l\/min frente a 100 l\/min; y un <u>40% m\u00e1s<\/u> en alta altitud 6400m 60 l\/min Vs. 42 l\/min.<\/p>\n\n\n\n<p>Este aspecto resulta interesante para realizar hipoxia en ejercicio; en principio los 2 sistemas bastar\u00edan para dar suministro en ejercicio moderado (un m\u00ednimo de 100 l\/min MAG-20) en funci\u00f3n de la intensidad de ejercicio, la altura a la que se planee ejercitar y el consumo de aire l\/min del sujeto expuesto a hipoxia.<\/p>\n\n\n\n<p>Otro aspecto diferenciador es que, el MAG-20 entrega el suministro de aire hip\u00f3xico en ciclos de r\u00e1fagas cada 4 segundos aproximadamente, con lo que hace necesario el uso de la bolsa de expansi\u00f3n de 50 litros que incorpora, para tener un suministro constante en las v\u00edas a\u00e9reas.<\/p>\n\n\n\n<p>El SUMMIT II por el contrario, entrega un flujo constante, lo cual hace innecesario el uso de bolsa de expansi\u00f3n en hipoxia en reposo, y en el caso de hipoxia en ejercicio, se usa un <a href=\"https:\/\/shop.biolaster.com\/es\/hipoxia\/87-hypoxicosetejercicio.html\" target=\"_blank\" rel=\"noopener noreferrer\">Set de Ejercicio<\/a> con un par de bolsas de expansi\u00f3n de tama\u00f1o m\u00ednimo.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Si est\u00e1s interesado en realizar entrenamiento en altitud simulada, ya sea con el fin de Aclimataci\u00f3n a la Altura, Mejora del Rendimiento o Salud, Biolaster te ofrece diversas opciones: Altipower Pro y los generadores de hipoxia&nbsp;Hypoxicators Vital Air \u2013 R3 \u2013 One Plus R3, Everest Summit II y MAG-20. Entre\u00a0 \u00e9stos, los generadores de hipoxia;\u00a0Mountain &hellip; <a href=\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/comparativa-generadores-hipoxia-mag-20-vs-summit-ii\/\" class=\"more-link\">Continuar leyendo<span class=\"screen-reader-text\"> &#8220;Comparativa Generadores de Hipoxia MAG-20 Vs SUMMIT II&#8221;<\/span><\/a><\/p>\n","protected":false},"author":11,"featured_media":355,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[16],"tags":[24,5,50,51],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v14.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Comparativa Generadores de Hipoxia MAG-20 Vs SUMMIT II<\/title>\n<meta name=\"description\" content=\"Presentamos una comparativa entre los Generadores de Hipoxia disponibles a la venta en Biolaster.\" \/>\n<meta name=\"robots\" content=\"index, follow\" \/>\n<meta name=\"googlebot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta name=\"bingbot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/comparativa-generadores-hipoxia-mag-20-vs-summit-ii\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Comparativa Generadores de Hipoxia MAG-20 Vs SUMMIT II\" \/>\n<meta property=\"og:description\" content=\"Presentamos una comparativa entre los Generadores de Hipoxia disponibles a la venta en Biolaster.\" \/>\n<meta property=\"og:url\" content=\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/comparativa-generadores-hipoxia-mag-20-vs-summit-ii\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog de Hipoxia\" \/>\n<meta property=\"article:published_time\" content=\"2018-02-01T10:35:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-07-26T06:44:09+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-content\/uploads\/sites\/5\/2018\/02\/comparativa-gen-e1517491014943.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"280\" \/>\n\t<meta property=\"og:image:height\" content=\"208\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/#website\",\"url\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/\",\"name\":\"Blog de Hipoxia\",\"description\":\"Otro sitio m\\u00e1s de Sitios Blogs - Biolaster\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/comparativa-generadores-hipoxia-mag-20-vs-summit-ii\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-content\/uploads\/sites\/5\/2018\/02\/comparativa-gen-e1517491014943.jpg\",\"width\":280,\"height\":208},{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/comparativa-generadores-hipoxia-mag-20-vs-summit-ii\/#webpage\",\"url\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/comparativa-generadores-hipoxia-mag-20-vs-summit-ii\/\",\"name\":\"Comparativa Generadores de Hipoxia MAG-20 Vs SUMMIT II\",\"isPartOf\":{\"@id\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/comparativa-generadores-hipoxia-mag-20-vs-summit-ii\/#primaryimage\"},\"datePublished\":\"2018-02-01T10:35:23+00:00\",\"dateModified\":\"2022-07-26T06:44:09+00:00\",\"author\":{\"@id\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/#\/schema\/person\/e82f4da14515a156407280db9b6ab4fd\"},\"description\":\"Presentamos una comparativa entre los Generadores de Hipoxia disponibles a la venta en Biolaster.\",\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/comparativa-generadores-hipoxia-mag-20-vs-summit-ii\/\"]}]},{\"@type\":[\"Person\"],\"@id\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/#\/schema\/person\/e82f4da14515a156407280db9b6ab4fd\",\"name\":\"comunicacion\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"http:\/\/www.biolaster.com\/blogs\/hipoxia\/#personlogo\",\"inLanguage\":\"es\",\"url\":\"http:\/\/2.gravatar.com\/avatar\/5e69dfea3299951ad9c042737820c598?s=96&d=mm&r=g\",\"caption\":\"comunicacion\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/posts\/343"}],"collection":[{"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/comments?post=343"}],"version-history":[{"count":16,"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/posts\/343\/revisions"}],"predecessor-version":[{"id":1524,"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/posts\/343\/revisions\/1524"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/media\/355"}],"wp:attachment":[{"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/media?parent=343"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/categories?post=343"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.biolaster.com\/blogs\/hipoxia\/wp-json\/wp\/v2\/tags?post=343"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}